Issue No. 03 · 2026

Asepsis Begins
at the Operating Table

Microbial contamination during liposuction: the weakest link in the chain of custody of autologous adipose tissue · LipAge Certified — Good Collection Practices Program
Executive Summary

Clinical studies show that up to 29% of lipoaspirate samples arrive at the laboratory with detectable microbial contamination — and this figure rises to 38% after thawing.

The implication is straightforward: inadequate asepsis in the surgical field is not only a risk to the patient during surgery — it also puts at risk the quality of the biological material that will be cryopreserved and used in a future procedure. Confirmed contamination is an absolute rejection criterion in the LipAge Score.

29%
contamination upon arrival at the laboratory
38%
post-thaw rate
23%
contamination in other autologous tissues
12.6%
bacterial contamination in bone allografts
01

Primary Contamination Vectors

  • Endogenous skin flora: the primary vector — Staphylococcus epidermidis, S. aureus and Corynebacterium spp. mechanically carried by the cannula
  • Contact contamination: the surgeon's gloves in contact with the cannula handle transfer microorganisms after just a few minutes of skin contact
  • Environmental contamination: in rooms without laminar airflow or adequate pressure, microbial particles settle on the field and containers
  • Inadequate instruments: cold sterilization (glutaraldehyde) does not eliminate rapidly growing atypical mycobacteria (RGM)
  • Delayed glove changes: the most frequently neglected measure — contaminated gloves that touch the cannula shaft transfer flora directly
02

Why Cryopreservation Does Not Solve the Problem

❄ What Cryopreservation DOES and DOES NOT Do

✅ DOES: Suspend all metabolic activity — bacteria remain inactive during storage in liquid N₂ (-196°C).

✅ DOES: Preserve adipose tissue cell viability for years when processing is adequate.

❌ DOES NOT: Sterilize. Cryopreserved bacteria survive thawing and resume metabolic activity.

❌ DOES NOT: Compensate for lapses in asepsis in the surgical field. The Cryopraxis laboratory receives what the surgeon sends.

Bucky & May (2017) documented an increase in the contamination rate from 29% (upon arrival) to 38% after thawing — suggesting that the thawing process may create favorable conditions for the multiplication of microorganisms already present.

03

Asepsis Protocol for LipAge Collection

Field Preparation — Before Incision

  • Cleanse with povidone-iodine surgical scrub or 4% chlorhexidine, followed by an alcohol-based antiseptic. Minimum contact time: 3 minutes. Allow to dry completely.
  • Cover the entire operative area with sterile surgical drapes. No nonsterile surface should be accessible within the field.

Equipment and Instruments

  • Sterilize exclusively in a steam autoclave — cold sterilization is NOT accepted for cannulas and suction tubing.
  • Use only the proprietary LipAge kit designed for direct collection into a closed sterile container.

Intraoperative Practice — Critical Point

  • Change gloves when switching donor sites or after any suspected contamination.
  • Never touch the cannula shaft with a glove that has been in contact with unprepared skin.
  • Keep the collection container in a closed system throughout collection.
04

LipAge Certified Checklist — Lipoaspirate Collection

Preoperative

  • LipAge kit available and intact (check seal and expiration date)
  • Instruments sterilized in a steam autoclave (do not accept cold sterilization)
  • Room with airflow control and cleaning in accordance with facility protocols

Field Preparation

  • Cleanse with chlorhexidine or povidone-iodine + alcohol-based antiseptic — allow to dry
  • Sterile drapes positioned before contact with any instrument
  • Sterile gloves checked before starting

Intraoperative

  • Do not touch the cannula shaft with a glove that has been in contact with unprepared skin
  • Change gloves when switching donor sites or after any suspected contamination
  • Keep the collection vessel in a closed system throughout collection
  • Surgical mask properly fitted; avoid talking over the open field

After Collection

  • Close and label the vessel immediately (name, date, time, site)
  • Place in a refrigerated transport container (2–8°C)
  • Contact the LipAge team for pickup — do not leave at room temperature for more than 4 hours
  • Do NOT freeze the material before shipping it to the Cryopraxis laboratory

References

  1. Bucky LP, May R Jr. Patient use of autologous cryopreserved intact adipose tissue. Cell and Tissue Engineering. 2017;1(3):224–235.
  2. Domenis R et al. Long-Term Biobanking of Intact Tissue from Lipoaspirate. Aesthet Surg J. 2019;39(Suppl_3):S44–S55. PMC6463172.
  3. Martínez-Rincón RO et al. Necrotizing soft tissue infection after liposculpture. Int J Surg Case Rep. 2020;77:536–540. PMC7710500.
  4. Cohen MS et al. Quality monitoring of microbial contamination of cryopreserved parathyroid tissue. Cell Tissue Bank. 2010;11(1):29–36.
  5. Eastlund T. Bacterial infection transmitted by human tissue allograft transplantation. Cell Tissue Bank. 2006;7(3):147–166.